The MT 5500
is one of the world's most popular walk-though metal detectors because it
provides maximum throughput with unparalleled multi-dimensional scanning. The MT
5500 meets the demanding needs of security professionals worldwide who trust its
ability to maintain a high flow rate with minimal alarms.
The MT 5500 includes 20 standard programs, which are maintained in an
electrically erasable non-volatile memory, for the ultimate in security
application versatility. The unit maintains all settings even when disconnected
from power and does not require recalibration when unit is turned OFF and back
ON. No battery is required for memory retention. When the unit is in operation,
a self-test of all systems is performed continuously with any failures or
problems reported on the LCD display.
Easy Assembly ![]()
Garrett's
MT 5500 is easily assembled with only 4 (four) pieces and 8 (eight) screws and
simple to follow instructions.
Multi-Dimensional Scanning The MT 5500 uses multi-dimensional
scanning which ensures maximum throughput and uniform screening with a minimum
of false alarms. Multiple coil circuitry with dual alarm lights inform operators
on which side of the detector the target is located. With "hot spots"
eliminated, the unit's detection field is uniform throughout the archway and
false alarms are significantly minimized.
Microprocessor Controlled State of the art microprocessors
ensure sensitivity and flexibility of programming with a maximum of 200 distinct
sensitivity levels in each program.
Audible and Visual Alarms Audible alarm with 3 distinct tones
indicating target on the left, right or center of the archway; two LED bar
graphs related to the red Alarm Lights that report detectable metal on either
side of the unit or centered within it.
Detection Field Unique coil design offers multidimensional
detection field with total uniformity both horizontally and vertically. This
design, plus a choice of three levels of ankle level boost, eliminates
traditional hot spots and weak signals. Target detection is precise regardless
of its location in the archway.
Access Control PanelThe Access Control Panel is designed for
use by authorized personnel with specific security codes. It allows authorized
users to change settings such as Program and Sensitivity. Security of the
detector's settings is maintained with a non-resettable sequence code, which
indicates every attempt at access to the settings. A tamper alarm sounds within
10 seconds after the Access touchpad is pressed unless a proper access code is
entered.
Specifications: Operating
Temperatures-4�F (-20� C) to +158�F (70�C); Humidity to 95%
non-condensing
Power Fully automatic 100 to 240 VAC, 50 or 60 Hertz, 5 watts; no
rewiring, switching or adjustments required. Power supply meets UL, CSA, TUV and
VDE standards
Weatherproofing / Foreign Object Protection StandardsMeets IP
31, IEC Standard. "Degrees of Protection provided by Enclosures," CEI 529
Tamper-Proof Dual-level access codes required to set or change all
sensitivity settings and detection programs; one level for use by supervisors in
selecting programs and sensitivity and the other for initial set-up and overall
control; non-resettable sequence code logs all attempts to access the settings.
Audible alarm reports any unauthorized attempt at access
Construction Attractive scratch and mar-resistant laminate
with resilient end caps; control panel and cross members of heavy duty aluminum.
Control Outputs Solid state switches (low voltage AC or DC)
for operating external alarms and control devices.
SynchronizationMultiple channels permit several MT 5500s and
other Garrett detectors to operate simultaneously in close proximity
Interference Suppression 100% sensor coil Faraday shielding;
RFI interference reduced with hardware; special Garrett built-in circuitry for
noise suppression and ignoring x-ray monitors. Physical interference minimized
by coil design and circuitry
Alarms Ready light indicates unit is operational; alarm lights and
audible alarms with variable tones are activated when the target amount of metal
is detected; location of alarm lights on left and right side of display combined
with variable tone indicates which side the of th person the target is located.
Infrared Sensor Provides traffic counter, helps eliminate "false
alarms and increases throughput
MaskingPrograms designed to eliminate the problem of
dissimilar targets canceling each other.
Warranty Limited 24 months, parts and labor
Dimensions35" (0.9 m)W x 87" (2.2 m)H x 23" (0.57 m)D