ACM8CBE![]()
ACM8CBE converts one (1) 12 to 24
volt AC or DC input into eight (8) independently controlled PTC protected
outputs. Outputs are activated by an open collector sink or normally open (NO)
dry trigger input from an Access Control System, Card Reader, Keypad, Push
Button, PIR, etc. The unit will route power to a variety of access control
hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders,
etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Unit is
designed to be powered by one common power source which will provide power for
both the board operation and locking devices, or two (2) totally independent
power sources, one (1) providing power for board operation and the other for
lock / accessory power. The FACP Interface enables Emergency Egress, Alarm
Monitoring, or may be used to trigger other auxiliary devices. The fire alarm
disconnect feature is individually selectable for any or all of the eight (8)
outputs |