| Sealed Lead Acid Battery |
|
| ELK-12260 |
12 Volts, 26
Ah |
| ELK Sealed Lead Acid
Batteries are excellent for the following applications with regard to size, Amp
hour rating, and proper terminal connections: battery backup (for Access Control
Systems, Fire Alarm Systems, and Security Alarm Systems), emergency lights,
lighted exit signs, and uninterruptible power supplies.
  | |
|     |
| SPECIFICATIONS: |
• Nominal Voltage:![]() • Rated
Capacity: • Length: • Width: • Height: • Weight: •
Terminals: |
12 Volts 26 AH  (20 hour
rate) 6.54" (166mm) 6.89" (175mm) 4.96" (126mm) 20.06 lbs
(9.1kg) B1-M5 bolt & nut | |
U.L.
Recognized Two Year Warranty |
|   |
|   ELECTRICAL
SPECIFICATIONS: |
Capacity 77°F(25°C) |
20 hour rate (1.3A) 10 hour rate
(2.38A)   5 hour rate (4.32A)   1 hour rate (15.6A) |
26AH 23.8AH 21.6AH 15.6AH |
Internal Resistance, Fully Charged
Battery (77°F) |
10mΩ |
  |
| Capacity affected by Temperature (20
hour rate) |
104°F (40°C)   77°F (25°C)   32°F
(0°C)       5°F (-15°C) |
102% 100%   85%  
65% |
| Charge Constant Voltage |
      Cycle: Initial Charging
Current less than 7.8A                           Voltage 14.4V - 15.0V at
77°F(25°C) Standby: Voltage 13.5V - 13.8V at 77°F(25°C) |
|
|